プロファイル Ⅱ・フィルター

Standard プロファイル® II Filter Elements.

Available in RF Series, RMF Series and AB Series—Code 3 and Code 7.

概要

プロファイル® II filters are all polypropylene.The elements have an absolute-rated downstream section, and a continuously graded pore size upstream section, which increases service life many-fold.

The materials of construction - chemically resistant polypropylene – permit application in a very wide range of corrosive and non-corrosive fluids.The fibers in プロファイル II filters may be considered continuous.No binder resin is used – the fibers are “bonded” by intertwining during the manufacturing process.As a result, プロファイル II filters show no media migration.

The プロファイル II filter has numerous applications in a broad range of industries that include chemical, petrochemical, photochemical, pharmaceutical, biological, electronic, magnetic tape, electroplating, food and beverage, cosmetic, veterinary, medical and fermentation industries.プレフィルターとしてもファイナルフィルターとしても使用することができます。

トップページへ

Operating Characteristics

Recommended maximum pressure differential is 60 psi up to 30°C (86°F), 50 psi up to 50°C (122°F), 30 psi up to 70°C (158°F), and 15 psi up to 82°C (180°F).

For applications where the filters are heated for any reason above 122°F (50°C) and the temperature is then reduced by 36°F (20°C) or more, AB Series elements are recommended.See Bulletin PRO 400 and PRE-1 for more detailed information.

Table I. プロファイル II Cartridge Grades And Their Characteristics
ろ過精度     Typical Clean Pressure Drop
液体用 Gaseous Service 液体用 Gaseous Service Typical Aqueous
Cartridge
Grade
Rating in µm At % Efficiency

99.9%



100%
DOP (0.3µm)(1)
Efficiency %
Aqueous Pressure
drop(2)
CFM of air per
PSIper 10" cartridge(3)
流量計
(GPM/10" Cartridge)
003* <0.5(4) <0.5(4) >99.9999 3.5 2.3 1 - 2.5
005 <0.5(4) <0.5(4) >99.9999 2.8 2.7 1 - 2.5
010 <0.5(4) 1 >99.9999 2.6 3.6 1 - 3
030 2.5 3 >99.9999 1.5 6.4 2~5
050 4 5 >99.9999 0.8 11.0 3~8
070 6 7 >99.9999 0.5 17.0 5~12
100 9 10 99.2 0.3 29.0 6~15
120 11 12 96.5 0.2 36.0 6~15
150 13 15 88 0.15 44.0 8~15
200 18 20 84.8 0.10 75.0 10~15
300 26 30 67 0.08 119.0 10~15
400 35 40 48.3 0.05 207.0 10~15
700 70 (5) 34 <0.05 415.0 10~15
900 90(4) (5) 25 <0.05 640.0 10~15
1200 120(4) (5) 10 <0.05 1000.0 10~15

(1) Air flow used for these data was 20 cfm/10" module, except grade 700, which was run at 4 cfm.
(2) Pressure drop is PSI per GPM for a single 10" module.For multiple elements, divide by number of modules.For fluids other than water, multiply by viscosity in centipoise.
(3) For longer modules, increase the flow rates listed in proportion.The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.
(4) Extrapolated values.
(5) Precise evaluation of the 100% removal efficiency for these coarse grades is not possible with test procedure utilized.
* AB style only.


トップページへ

Sizes

The プロファイル II RF, and RMF Series filter elements are 21/2" O.D. and are available in one piece 10", 20", 30", and 40" length modules.プロファイル II elements are also available in 23/4" diameter

AB Code 3, 7 and 8 Series configurations.See Bulletin PRO 400 for further details.

トップページへ

Part Numbers / Ordering Information

Table II. Standard Configurations of プロファイル II Cartridges

  プロファイル II Element Part Numbers  
100% Removal Rating, µm For General Application For General Application Including In-Situ Steam Sterilization,and In-Situ Hot Water Sanitizing(1)
  RF Series AB Series
0.3* (2) AB Y003
0.5 (2) R F005 AB Y005
1 R F010 AB Y010
3 R F030 AB Y030
5 R F050 AB Y050
7 R F070 AB Y070
10 R F100  
12 R F120  
15 R F150  
20 R F200  
30 R F300  
40 R F400  
70 R F700  
90 R F900  
120 R F1200  

 
Gasket Code
なし No Symbol
Elastomeric Material** M***



   
Nominal Length, In. Code
10 1
20 2
30 3
40 4



 
Gasket Material Code
Alloy of Polypropylene and Ethylene Propylene Diene Monomer (EPDM) H21



 
用途 Code
医薬品関連 P
その他 Omit



 
O-Ring Option Code
シリコン H4
バイトンA H
Ethylene-Propylene J



         
Cartridge Diameter O.D., In. Adapter Configuration Number of O-Rings O-Ring Size FDA Listed Materials of Construction Code
2 3/4 Flat Top 2 222 Yes 3
2 3/4 Finned Top, Locking Tabs 2 226 Yes 7
2 3/4 Finned Top 2 222 Yes 8

(1) Only P grade AB Series elements may be in-situ steam sterilized.
(2) Extrapolated valves.
* AB style only.
** Provides a positive sealing surface to eliminate potential fluid bypass in competitive housings with blunt knife edges.
*** When the M symbol is selected the part number must end in H21 code.





Table III.Housings For プロファイル II Elements

Type Of Element Housing Available
R  F Series and RM F Series See Housing Data Sheets H2, H13, H14, H15, H16, H17, H18, H19, H36, H37, H38 and H39 for Pall housings specifically designed toaccommodate these elements.
R  F Series elements may also be used with competitor built housings which accommodate 21/2" O.D. x 10", 20", 30", and 40" nominal length elements; however,sealing may be marginal for grades 030 (3µm absolute) and finer.
AB  Y Series, Code 3, 7 and 8 See Housing Data Sheets H22, H26, H28, H29, H30, H31, H32, and H35.


トップページへ